The actual instructions of how to perform the calibration procedure and what to
do at each step is given on the FlexPendant. You will be guided through the
calibration procedure, step by step.
Wrist Optimization method
Wrist Optimization is a method for improving reorientation accuracy for continuous
processes like welding and gluing and is a complement to the standard calibration
method.
The actual instructions of how to perform the wrist optimization procedure is given
on the FlexPendant.
CalibWare - Absolute Accuracy calibration
The CalibWare tool guides through the calibration process and calculates new
compensation parameters. This is further detailed in the
Application
manual - CalibWare Field
.
If a service operation is done to a robot with the option Absolute Accuracy, a new
absolute accuracy calibration is required in order to establish full performance.
For most cases after replacements that do not include taking apart the robot
structure, standard calibration is sufficient.
The Absolute Accuracy option varies according to the robot mounting position.
This is printed on the robot name plate for each robot. The robot must be in the
correct mounting position when it is recalibrated for absolute accuracy.
References
Article numbers for the calibration tools are listed in the section
.
Product manual - CRB 1100
655
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
6 Calibration
6.1.2 Calibration methods
Continued
Summary of Contents for CRB 1100
Page 1: ...ROBOTICS Product manual CRB 1100 ...
Page 162: ...This page is intentionally left blank ...
Page 184: ...This page is intentionally left blank ...
Page 652: ...This page is intentionally left blank ...
Page 698: ...This page is intentionally left blank ...
Page 712: ...This page is intentionally left blank ...
Page 714: ...This page is intentionally left blank ...
Page 719: ......