Note
Action
Ring of the axis-2 sealing assembly
tool, included in Special toolkit for
IP67 robots (3HAC078203-001).
For robots with protection class IP67 (option
3350-670)
Place the ring of the axis-2 sealing assembly tool
against the sealing.
5
xx2000002463
xx2000002562
Small circular plate of the axis-2
sealing assembly tool, included in
Special toolkit for IP67 robots
(3HAC078203-001).
Fit the small circular plate of the axis-2 sealing
assembly tool and fix with three M6x75 screws.
6
xx2000002464
xx2000002465
Screw the screws, little by little and evenly, to
press the sealing into place.
7
Remove the assembly tool.
8
Check that the sealing is undamaged and properly
fitted.
9
Refitting the swing to the base
Note
Action
See
.
Check the axis-2 mechanical stops.
Replace if damaged.
1
Continues on next page
300
Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the swing
Continued