Note
Action
DANGER
Make sure all safety requirements are met
when performing the first test run.
8
Jogging the robot to zero position
Note
Action
Turn on the electric power to the robot.
1
If the robot is not connected to the controller,
power must be supplied to the connector R1.MP
according to
Supplying power to connector R1.MP
xx2000001520
Jog all axes to zero position.
2
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the safeguarded
space.
3
Concluding procedure
Note
Action
Calibration is detailed in section
Recalibrate the robot.
1
DANGER
Make sure all safety requirements are met when
performing the first test run. See
installation, maintenance, or repair on page 164
2
Product manual - CRB 1300
377
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the lower arm
Continued
Summary of Contents for CRB 1300
Page 1: ...ROBOTICS Product manual CRB 1300 ...
Page 50: ...This page is intentionally left blank ...
Page 662: ...This page is intentionally left blank ...
Page 690: ...This page is intentionally left blank ...
Page 704: ...This page is intentionally left blank ...
Page 720: ...This page is intentionally left blank ...
Page 725: ......