Note
Action
xx2000001513
Open the oil plugs, one for filling and the
other for venting.
3
WARNING
Overfilling of gearbox lubricant can lead to
internal over-pressure inside the gearbox
which in turn may:
•
damage seals and gaskets
•
completely press out seals and
gaskets
•
prevent the robot from moving
freely.
4
Type of oil and total amount is detailed in
Technical reference manual - Lubrication
in gearboxes
.
Refill the gearbox with oil.
Note
The amount of oil to be filled depends on
the amount previously being drained.
5
Tightening torque: 10 Nm
Refit the oil plugs.
6
Concluding procedure
Note
Action
Calibration is detailed in section
Recalibrate the robot.
1
DANGER
Make sure all safety requirements are met when
performing the first test run. See
installation, maintenance, or repair on page 164
2
494
Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.