Removing the axis-3 motor
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
Removing motors will release axes. This means
the axes can fall down.
Make sure axes are well supported before remov-
ing motors.
2
xx2000001616
Remove the screws and washers.
3
xx2000001617
Carefully lift out the motor.
4
Refitting the motor
Use these procedures to refit the axis-3 motor.
Refitting the axis-3 motor
Note
Action
Axis-3 motor for CRB 1300-7/1.4:
3HAC073086-001
CAUTION
Do not mix the axis-3 motor used for CRB 1300-
7/1.4 and .
Always carefully check the part number attached
to the motor and the robot type, and refit with the
right one.
1