Note
Action
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
3
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (4 pcs)
Refit the process hub.
4
Tightening torque: 2.6 Nm
xx2200001000
Securing the cable package in the tubular
Note
Action
Screw: M4x12 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Refit the first semicircular bracket to fix the cable
package.
1
Tightening torque: 2.6 Nm
xx2000001748
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (2 pcs for each plate)
Refit the connector plate.
2
Tightening torque: 1.3 Nm
xx2000001531
Continues on next page
Product manual - CRB 1300
629
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.7.3 Replacing the axis-3 gearbox
Continued