Note
Action
xx2200001133
The brake will be enable as soon as the button is
released.
3
Supplying power to connector R1.MP
If the robot is not connected to the controller, power must be supplied to connector
R1.MP on the robot, in order to enable the brake release buttons.
Note
Action
DANGER
Incorrect connections, such as supplying power
to the wrong pin, may cause all brakes to be
released simultaneously and instantly!
1
xx1900001654
Supply
•
0V on pin 12.
•
24V on pin 11.
Note
Do not interchange the 24V and 0V pins.
If they are mixed up, damage can be caused to
internal electrical components.
2
Use the brake releasing button as described in
Releasing the brakes on page 65
.
3
66
Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.3.2 Manually releasing the brakes
Continued
Summary of Contents for CRB 1300
Page 1: ...ROBOTICS Product manual CRB 1300 ...
Page 50: ...This page is intentionally left blank ...
Page 662: ...This page is intentionally left blank ...
Page 690: ...This page is intentionally left blank ...
Page 704: ...This page is intentionally left blank ...
Page 720: ...This page is intentionally left blank ...
Page 725: ......