Configuring the laser scanner(s)
Laser scanner configuration depends on the type and number of scanners
connecting to the robot and RobotWare version. Refer to the following table for
applicable scenario and proceed to specific section for configuration details.
Refer to...
Re-
quire...
RobotWare ver-
sion
Number
of
connected
scanners
Works with...
Scanner type
Collaborative
Speed
Con-
trol
add-in
OmniCore
controller
with
SafeMove
Scalable
I/O
device
DSQC1042
PLC
Y
RobotWare 7.7 or
later
1
Y
N
Y
PROFIsafe-based
Y
RobotWare 7.7 or
later
2
Y
N
Y
Y
RobotWare 7.10 or
later
1
Y
N
N
Y
RobotWare 7.10 or
later
2
Y
N
N
Configuration of one SafetyIO-base
laser scanner (RobotWare 7.6 or
later) on page 145
Y
RobotWare 7.7 or
later
1
Y
Y
N
SafetyIO-based
Configuration of two SafetyIO-base
laser scanners (RobotWare 7.6 or
later) on page 150
Y
RobotWare 7.7 or
later
2
Y
Y
N
Product manual - CRB 1300
93
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.3.8 Installation of laser scanner
Continued
Summary of Contents for CRB 1300
Page 1: ...ROBOTICS Product manual CRB 1300 ...
Page 50: ...This page is intentionally left blank ...
Page 662: ...This page is intentionally left blank ...
Page 690: ...This page is intentionally left blank ...
Page 704: ...This page is intentionally left blank ...
Page 720: ...This page is intentionally left blank ...
Page 725: ......