DCS500 Pin and Parameter list
A 112
SIG6(LOAD SHARE)
Signal of FREE_SIGNALS-function block
( S2,S16/16 )
This block is containing signals which can be set by the CMT or panel.
Value which can be used to give control
load sharing
in master/follower drives. Before the
drive will use this value, it has to be connected to the load sharing input
SEL1.[LOAD_SHARE] (2403).
12521
FB_O: I2
SC: -
HL: 30000
LL: -30000
D: 4000
U: -
SIG7(FLUX REF)
Signal of FREE_SIGNALS-function block
( S2,S16/16 )
This block is containing signals which can be set by the CMT or panel.
Value which can be used to give a
flux reference
. Before the drive will follow this
reference, it has to be connected to the flux reference input [FLUX_REF] (1002).
12522
FB_O: I2
SC: -
HL: 30000
LL: -30000
D: 4095
U: -
SIG8(EMF REF)
Signal of FREE_SIGNALS-function block
( S2,S16/16 )
This block is containing signals which can be set by the CMT or panel.
Value which can be used to give an
emf reference
. Before the drive will follow this
reference, it has to be connected to the emf reference input [EMF_REF] (1003).
12523
FB_O: I2
SC: -
HL: 30000
LL: -30000
D: 3786
U: -
SIG9(FORCE FWD)
Signal of FREE_SIGNALS-function block
( S2,S16/16 )
This block is containing signals which can be set by the CMT or panel.
Value which can be used to give a force command to
field logic
. Before the drive will
follow this command, it has to be connected to the force forward-input [F1_FORCE_FWD]
(1302).
12524
FB_O: B
SC: -
HL: 30000
LL: -30000
D: 0
U: -
SIG10(FORCE REV)
Signal of FREE_SIGNALS-function block
( S2,S16/16 )
This block is containing signals which can be set by the CMT or panel.
Value which can be used to give a force command to
field logic
. Before the drive will
follow this command, it has to be connected to the force reverse-input [F1_FORCE_REV]
(1303).
12525
FB_O: B
SC: -
HL: 30000
LL: -30000
D: 0
U: -
SIG11(CURR. REF)
Signal of FREE_SIGNALS-function block
( S2,S16/16 )
This block is containing signals which can be set by the CMT or panel.
Value which can be used to give a
current reference
. Before the drive will follow this
reference, it has to be connected to the current contoller input [CURR_REF] (402).
12526
FB_O: I2
SC: -
HL: 30000
LL: -30000
D: 0
U: -
SIG12(CURR. STEP)
Signal of FREE_SIGNALS-function block
( S2,S16/16 )
This block is containing signals which can be set by the CMT or panel.
Value which can be used to give a
current step
. Before the drive will follow this step, it
has to be connected to the current contoller step input [CURR_STEP] (403).
12527
FB_O: I2
SC: -
HL: 30000
LL: -30000
D: 0
U: -