2.1.2 Installing base devices
General
The I/O devices are designed to be mounted vertically on a mounting rail in an
IP20 protected environment with normal air convention. Forced air is needed if the
devices are mounted horizontally.
The base device communicates over the EtherNet/IP communication protocol to
the robot controller or to other EtherNet/IP scanners. Up to 20 devices in total can
be connected to the robot controller over EtherNet/IP, this includes base devices
and other third-party I/O devices.
When the base device is connected to logic power supply and Ethernet it can be
detected and configured by the robot controller. The process power supply powers
the inputs, outputs, and the optical interface to the add-ons.
xx1600002033
Installing base devices
Use this procedure to install the base device. See also the product manual for the
robot controller, listed in
.
Note
Action
DANGER
Before commencing any work inside the cabinet
make sure that the main power has been switched
off.
1
Continues on next page
16
Application manual - Discrete I/O
3HAC070208-001 Revision: C
© Copyright 20192020 ABB. All rights reserved.
2 Hardware overview
2.1.2 Installing base devices
Summary of Contents for Discrete I/O
Page 1: ...ROBOTICS Application manual Discrete I O ...
Page 6: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 56: ......