General Information and Ratings 2-5
MN448
2.3.2 Integrated Motor / Drive Model Numbers and Ratings
The following section provides details on the EC Titanium Integrated Motor and Drive. Voltage shown is at the input of the
drive. All motors are either 3-phase 230V AC or 3-phase 460V AC.
Table 2-3 Top Mount Motor and Drive Ratings
Type
HP
Motor
Frame
Motor
Efficiency
Motor
Amps
Drive
Model
Drive
Size
Drive Input
Amps (I
1N
)
Drive
Output
Amps (I
2N
)
1-phase 100V…115V AC (+/-10%) - 3 Phase 230V Output
ECS100T1H1DF4
1
140
89.3%
2.4
ECI1A3P2
1
10.3
3.2
1-phase 200…240V AC (+/-10%) - 3 Phase 230V Output
ECS100T8H1DF4
1
140
89.3%
2.4
ECI8A7P0
1
7.1
7.0
ECS100T8H2DF4
2
140
90.7%
4.4
ECI8A7P0
1
12.5
7.0
ECS100T8H3DF4
3
140
91.4%
7.0
ECI8A7P0
1
13.3
7.0
ECS100T8H3EF4
3
180
93.7%
6.9
ECI8A7P0
1
12.7
7.0
3-phase 200…240V AC (+/-10%) - 3 Phase 230V Output
ECS100T2H1DF4
1
140
89.3%
2.4
ECI2A4P3
1
3.6
4.3
ECS100T2H2DF4
2
140
90.7%
4.3
ECI2A4P3
1
6.5
4.3
ECS100T2H3DF4
3
140
91.4%
6.7
ECI2A7P0
1
9.7
7.0
ECS100T2H3EF4
3
180
92.8%
7.3
ECI2A7P0
1
9.3
7.0
ECS100T2H5EF4
5
180
93.7%
10.5
ECI2A10P5
2
12.6
10.5
3-phase 380…480V AC (+/-10%) - 3 Phase 460V Output
ECS100T4H1DF4
1
140
89.3%
1.2
ECI4A2P2
1
1.8
2.2
ECS100T4H2DF4
2
140
90.7%
2.2
ECI4A2P2
1
3.2
2.2
ECS100T4H3DF4
3
140
91.4%
3.5
ECI4A4P1
1
4.7
4.1
ECS100T4H3EF4
3
180
92.8%
3.7
ECI4A4P1
1
4.7
4.1
ECS100T4H5EF4
5
180
93.7%
5.3
ECI4A5P8
1
7.1
5.8
ECS100T4H7EF4
7.5
180
94.0%
8.8
ECI4A9P5
2
10.0
9.5
ECS100T4H7FF4
7.5
210
94.7%
8.6
ECI4A12P0
2
9.5
12.0
ECS100T4H10FF4
10
210
94.8%
11.0
ECI4A12P0
2
10.1
12.0
Note
: EC Titanium integrated motor and drives are factory programmed with the values for BEMF, R, Ld and Lq. If the drive
parameters have been reset to factory defaults, refer to the motor nameplate for values used to program the drive unit
(see Table 2-1 Motor Setup Parameter Listing).
I
1N
Continuous rms input current (measured value for integrated motor and drive).
I
2N
Continuous rms output current. 50% overload is allowed for one minute every ten minutes.
Maximum output current is 75% overload for 2.5 seconds of I
2N
.
Summary of Contents for EC Titanium Series
Page 1: ... MN448_May 2020 May 2020 EC Titanium Manual User s guide ...
Page 10: ...1 4 Introduction MN448 ...
Page 20: ...3 4 Mechanical Information and Mounting MN448 ...
Page 26: ...4 6 Electrical Installation and Planning MN448 ...
Page 32: ...5 6 Control Pad Wiring and Keypad Interface MN448 ...
Page 36: ...6 4 Keypad Programming and Basic Operation MN448 ...
Page 44: ...8 4 Parameter Navigation and Groups MN448 ...
Page 51: ...9 7 Control Modes MN448 ...
Page 77: ...11 8 Standalone Motor and ABB Drive Setup MN448 ...
Page 99: ...A 12 Modbus RTU Example Connection MN448 ...
Page 102: ......