background image

 

Note:

The specifications, data, design or other information contained in this document (the
“Brochure”) - together: the “Information” - shall only be for information purposes and shall in
no respect be binding. The Brochure does not claim to be exhaustive. Technical data in the
Information are only approximate figures. We reserve the right at any time to make technical
changes or modify the contents of this document without prior notice. The user shall be
solely responsible for the use of any application example or information described within this
document. The described examples and solutions are examples only and do not represent
any comprehensive or complete solution. The user shall determine at its sole discretion, or as
the case may be, customize, program or add value to the Hitachi ABB Power Grids products
including software by creating solutions for the end customer and to assess whether and to
what extent the products are suitable and need to be adjusted or customized.

This product is designed to be connected to and to communicate information and data
via a network interface. It is the users sole responsibility to provide and continuously
ensure a secure connection between the product and users or end customers network
or any other network (as the case may be). The user shall establish and maintain any
appropriate measures (such as but not limited to the installation of firewalls, application
of authentication measures, encryption of data, installation of anti-virus programs, etc) to
protect the product, the network, its system and the interface against any kind of security
breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or
information. Hitachi ABB Power Grids is not liable for any damages and/or losses related to
such security breaches, any unauthorized access, interference, intrusion, leakage and/or theft
of data or information.

Hitachi ABB Power Grids shall be under no warranty whatsoever whether express or implied
and assumes no responsibility for the information contained in this document or for any
errors that may appear in this document. Hitachi ABB Power Grids's liability under or in
connection with this Brochure or the files included within the Brochure, irrespective of the
legal ground towards any person or entity, to which the Brochure has been made available,
in view of any damages including costs or losses shall be excluded. In particular Hitachi ABB
Power Grids shall in no event be liable for any indirect, consequential or special damages,
such as – but not limited to – loss of profit, loss of production, loss of revenue, loss of
data, loss of use, loss of earnings, cost of capital or cost connected with an interruption of
business or operation, third party claims. The exclusion of liability shall not apply in the case
of intention or gross negligence. The present declaration shall be governed by and construed
in accordance with the laws of Switzerland under exclusion of its conflict of laws rules and of
the Vienna Convention on the International Sale of Goods (CISG). 

Hitachi ABB Power Grids reserves all rights in particular copyrights and other intellectual
property rights. Any reproduction, disclosure to third parties or utilization of its contents -
in whole or in part - is not permitted without the prior written consent of Hitachi ABB Power
Grids.

ABB is a registered trademark of ABB Asea Brown Boveri Ltd.
Manufactured by/for a Hitachi Power Grids company.

© 2020 Hitachi Power Grids.

All rights reserved.

34

1KGT151042

 

V000 1

Summary of Contents for EDS500 Series

Page 1: ...Power Grids EDS500 series FSK modems Part 1 Devices Manual Release 1 Power Grids EDS500 series FSK modems Part 1 Devices Manual Release 1...

Page 2: ...Revision Revision Document identity 1KGT151042 V000 1 Revision Date Changes 0 08 2019 Initial version 2 1KGT151042 V000 1...

Page 3: ...k structures 13 3 3 1 Line topology 13 3 3 2 Point to point topology 13 3 3 3 Star topology 14 3 3 4 Multidrop star topology 15 4 Device description 17 4 1 Compact device 500FSD10 17 4 1 1 Overview 50...

Page 4: ...Alarm relay X4 26 4 5 5 Serial interface for configuration Con0 27 4 5 6 Extension interface EXT 27 4 6 Display elements 28 4 7 Controls 28 4 7 1 Reset button 28 4 8 Maintenance 29 5 Glossary 31 4 1KG...

Page 5: ...Part 2 Functions Description of the functions 1KGT151044 Part 3 Command reference Description of the command line interface Table 1 Parts of the Manual EDS500 series FSK modems 1 2 References 1 Indivi...

Page 6: ...References Introduction 6 1KGT151042 V000 1...

Page 7: ...ituation which if not avoided could result in death or serious injury of operating personnel CAUTION Hazardous situation which if not avoided could result in minor or moderate injury ADVICE Important...

Page 8: ...V DC EN 50274 DIN VDE 0660 514 Low voltage switchgear and controlgear assemblies Protection against electric shock Protection against unin tentional direct contact with hazardous live parts IEC EN 60...

Page 9: ...health life safety or property under normal circumstances Intended use of the product means that the components of the EDS500 series are operated and maintained exclusively in the form described in t...

Page 10: ...device is operating WARNING No plug shall be freely accessible in normal operation due to safety reasons WARNING Connect the device only if you can make sure that the specifications are kept ADVICE E...

Page 11: ...which require the need for cost efficient reliable communication The following table shows the technical features of the FSK modems Feature 500FSD10 500FSD11 500FSD20 Transmission stan dard CCITT V 2...

Page 12: ...s ITU T CCITT R 37 6 channels each 200 bps ITU T CCITT R 38a 2 channels each 600 bps 1 channel 1200 bps ITU T CCITT V 23 1 channel 2400 bps 1 channel 9600 bps 500FSD devices can be used in point to po...

Page 13: ...same copper cable via two or four wires In this so called partyline or multidrop configuration the application protocol provides a polling scheme to query and control the different stations 500FSDxx...

Page 14: ...h a central connection point The different connections for the stations are bundled in the control center and are attached to a single 500FSD analog modem For star topologies two or four wire cabling...

Page 15: ...multiple transmission lines to a central point like a control center Control center Cu 500FSDxx Sta on 1 500FSDxx RTU IED Sta on 3 500FSDxx RTU IED Sta on 2 1 RTU IED Sta on 4 1 500FSDxx RTU IED Cu Cu...

Page 16: ...Network structures System concept 16 1KGT151042 V000 1...

Page 17: ...with the frequency shift keying method FSK The modem can operate in two and four wire connection The mode of operation is set by means of a twelve fold DIP switch 4 1 2 Front view and connectors 500F...

Page 18: ...5 mm Cooling thermal convection no moving parts Enclosure protection class IP20 Weight 150 g Power supply input X1 Operating voltage 24 60 V DC 15 20 Power consumption typical 2 W Current demand peak...

Page 19: ...ter 4 5 Connections General Data Type of modulation Frequency shift keying FSK with carrier switch off for multi drop network Type of communication Point to point or multi drop network Operation modes...

Page 20: ...b M1 M2 M5 D2 GND D1 S2 AK1 MK1 RK1 S1 2 DSR CTS DCD RxD TxD RTS DTR E2 Figure 11 Block diagramm 500FSD20 The 500FSD20 modem is a voice frequency telegraphy unit VFT unit which operates according to t...

Page 21: ...f duplex via two four wire links Channel assignment according to CCITT raster R 35 R 37 R 38A V 23 1200 baud additional options 600 baud or 2400 baud channel Mechanical layout Dimensions 99 x 45 x 115...

Page 22: ...ntal conditions mechanical Vibration sinusoidal Test Fc IEC 60068 2 6 3 mm 3 9 Hz 10 m s 9 200 Hz 1 octave min 10 cycles per axis ETSI EN 300 019 1 3 class 3 4 IEC 60721 3 3 class 3M5 3 5 mm 3 9 Hz 10...

Page 23: ...als The power lead has to be sufficiently fused and a manual interrupter for the power supply has to be installed emergency switch For the full effect of the overvoltage protection the functional eart...

Page 24: ...mal operation due to safety reasons ADVICE Due to the internal overvoltage protection interrupt any connection to ground of the device for the time of the measurement before you carry out isolation me...

Page 25: ...on ES2 acc IEC 62368 1 Plug type Phoenix Contact MSTBT 2 5 4 ST Galvanic isolation 3 kV isolation voltage Overvoltage protection line to earth 4 kV line to line 2 kV Electrical fast transient Burst IE...

Page 26: ...C Switching current 500 mA Plug type Phoenix Contact MSTBT 2 5 4 ST Circuit classification Overvoltage protection line to earth 4 kV line to line 2 kV Electrical fast transient Burst IEC 61000 4 4 4 k...

Page 27: ...A RS 232 Data rate 57 6 kbps 8 data bits no parity 1 stop bit Plug type RJ 12 6P6C Cable shielded RS 232 cable Adapter cable 500CAB06 1KGT038912R0001 RJ12 to SubD9F DTE PC Circuit classification ES1 a...

Page 28: ...is detected for more than a baudrate dependent time off tranmitter receiver test func tion inactive EQZ Equalizer flash yellow 0 Hz best result 25 Hz worst result off No activity on the Con0 inter fac...

Page 29: ...ed communication connections will be lost temporarily during restart 4 8 Maintenance EDS500 series devices do not require any maintenance There are no wear and tear parts There are no moving parts The...

Page 30: ...Maintenance Device description 30 1KGT151042 V000 1...

Page 31: ...DTE Data Terminal Equipment DTR Data Terminal Ready ETSI European Telecommunications Standards Institute FSK Frequency shift keying GND Ground IEC International Electrotechnical Commission ITU T Inte...

Page 32: ...Glossary 32 1KGT151042 V000 1...

Page 33: ...1KGT151042 V000 1 33...

Page 34: ...nd or theft of data or information Hitachi ABB Power Grids is not liable for any damages and or losses related to such security breaches any unauthorized access interference intrusion leakage and or t...

Reviews: