Endura AZ series integral and remote transmitter
Combustion oxygen monitor
5 Programming
IM/AZ20E–EN Rev. F
45
5.4.4 Device Setup
Used by
Advanced
users to set the instrument tag, specify the
type of probe, select cable length, set oxygen and
temperature ranges and to setup passwords for access at all
levels.
Standard
users have read-only privileges (except at the
Security Setup
level) and
Read Only
users have read-only
privileges for a reduced set of menu options.
Parameter
Comment / [Range]
Default
Instrument Tag
Used to enter a tag (ID) of up to 20 characters in length for
the transmitter.
Characters are selected from an alphanumeric list.
The 'Instrument Tag' is not displayed in the
Operator
page(s) when a
Display Mode
of
3 x 9
is selected – see
N / A
Probe Type
Selects the probe type to be used with the transmitter.
AZ20 & Remote Tx
AZ20 &
Remote Tx*
AZ20 & Integral Tx
AZ25 & Remote Tx
AZ30 & Integral Tx
AZ30 & Remote Tx
AZ35 & Remote Tx
AZ10 With Filter
AZ10 No Filter
Cable Length
The length in metres of the cable between the probe and
the remote transmitter. This length is used in the cold
junction measurement to compensate for the impedance
of the cable.
[0 to 100 m]
Note
. Applicable only to remote transmitters.
0 m
*For marine application Exhaust Gas Recirculation (EGR) transmitters, the probe type is set to
AZ10 No
Filter
and cannot be changed.
Table 5.9 Device Setup Menu
4
Menu
Exit
Select
Device Setup