Endura AZ30 series integral probe and remote transmitter
Combustion oxygen monitor
6 Programming
COI/AZ30E–EN Rev. D
49
6.4.4 Device Setup
Used by
Advanced
users to set the instrument tag, specify the
type of probe, select cable length, set oxygen and
temperature ranges and to setup passwords for access at all
levels.
Standard
users have read-only privileges (except at the
Security Setup
level) and
Read Only
users have read-only
privileges for a reduced set of menu options.
Parameter
Comment / [Range]
Default
Instrument Tag
Used to enter a tag (ID) of up to 20 characters in length for
the transmitter.
Characters are selected from an alphanumeric list.
The 'Instrument Tag' is not displayed in the
Operator
page(s) when a
Display Mode
of
3 x 9
is selected – see
Section 6.4.5, page 52.
N / A
Probe Type
Selects the probe type to be used with the transmitter.
AZ20 & Integral Tx
Factory-set
AZ20 & Remote Tx
AZ25 & Remote Tx
AZ30 & Integral Tx
AZ30 & Remote Tx
AZ35 & Remote Tx
Cable Length
The length in metres of the cable between the probe and
the remote transmitter. This length is used in the cold
junction measurement to compensate for the impedance
of the cable.
[0 to 100 m]
Note
. Applicable only to remote transmitters.
0 m
Table 6.9 Device Setup Menu