Conveyor subsystem
Col-
or
Description
Symbol
Pos.
R
Timeout inconveyor.
TIMEOUT_IN_POSITION
91 310
Place parts on belt and reset inconveyor.
B
No details on inconveyor. Load new details
on inconveyor.
ALARM_PARTS_LOW_BELT1
91 311
R
Part went to far on inconveyor.
ALARM_TOO_FAR_BELT1
91 312
Remove part and reset inconveyor.
R
Emergency stop.
ALARM_EMER-
GENCY_STOP_BELT1
91 313
Reset cell to normal operation state.
R
Alarm frequency inverter inconveyor.
ALARM_FC_BELT1
91 314
Check frequency inverter and inconveyor.
R
Alarm frequency inverter outconveyor.
ALARM_FC_OUTBELT1
91 315
Check frequency inverter and outconveyor.
R
Timeout manual run forward inconveyor.
TIMEOUT_MANUAL_FOR-
WARD_BELT1
91 316
Restart belt with run forward knob.
R
Timeout manual run backward inconveyor.
TIMEOUT_MANUAL_BACK-
WARD_BELT1
91 317
Restart belt with run backward knob.
R
Timeout emptying outconveyor.
TIMEOUT_EMPTYING_OUT-
BELT1
91 318
Restart outconveyor with outconveyor
auto/manual switch.
R
Part reached end of outconveyor. Remove
part.
ALARM_TOO_FAR_OUTBELT1
91 319
Restart outconveyor with outconveyor
auto/manual switch.
R
Faulty signal from TooFar sensor outconvey-
or.
ALARM_TOO_FAR_FAULTY_OUT-
BELT1
91 320
Check sensor function.
R
Inconveyor is in manual mode and cannot be
controlled by robot when necessary.
ALARM_IN_BELT_MANU-
AL_MODE
91 321
R
Robot is blocking possibility for emptying
mode. Wait for robot block signal to reset or
reset it manually.
ALARM_RO-
BOT_BLOCK_EMPTYING
91 322
B
Outconveyor in emptying mode.
OUT_BELT_IN_EMPTYING
91 323
R
Robot is not allowed to leave on outconveyor.
Empty outconveyor and make sure that is is
in auto mode.
ROBOT_CANT_LEAVE_OUT-
BELT
91 324
FlexLoader Vision
Alarms for the FlexLoader Vision system are described in the FlexLoader Vision
manual.
Troubleshooting information concerning FlexLoader Vision, e.g. teachin or accuracy
problems, can be found in the FlexLoader Vision manual.
Other FlexLoader Vision related problems can often be solved by checking the
FlexLoader Vision generated log-file. Refer to the FlexLoader Vision manual for
information on extended logging.
Continues on next page
Product manual - FlexLoader SC 6000
167
3HAC051768-001 Revision: D
© Copyright 2014-2020 ABB. All rights reserved.
11 Troubleshooting
11.1 Alarms, warnings and informations and troubleshooting
Continued
Summary of Contents for FlexLoader SC 6000
Page 1: ...ROBOTICS Product manual FlexLoader SC 6000 ...
Page 8: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 78: ...This page is intentionally left blank ...
Page 172: ...This page is intentionally left blank ...
Page 174: ...This page is intentionally left blank ...
Page 176: ...This page is intentionally left blank ...
Page 178: ...This page is intentionally left blank ...
Page 182: ...This page is intentionally left blank ...
Page 184: ...This page is intentionally left blank ...
Page 186: ...This page is intentionally left blank ...
Page 192: ...This page is intentionally left blank ...
Page 224: ...This page is intentionally left blank ...
Page 283: ......