F.8 FlexLoader options functionality
Overview
The FlexLoader options functionality is structured according to the following
overview.
Description
Module
Contains helper functions for setting up and controlling the air
cleaning unit. Could be loaded in all motion tasks but currently
only prepared for T_ROB1.
AirClean.sys
Contains helper functions for setting up and controlling the
marking unit. Could be loaded in all motion tasks but currently
only prepared for T_ROB1.
MarkingUnit.sys
Contains some task general data definitions. Could be loaded in
all motion tasks but currently only prepared for T_ROB1.
MarkingUnit_shared.sys
Handles the user interaction for statistical outlet, for example re-
questing sample part, aborting sample. Loaded into own back-
ground task.
StatisticalOutlet.mod
Contains helper functions for setting up and controlling the stat-
istical outlet. Loaded into T_ROB1 task.
StatisticalOutlet.sys
Shared module containing some task general data definitions.
StatisticalOut-
let_shared.sys
Contains a couple of data definitions used for turn station. Could
be loaded in all motion tasks but currently only prepared for
T_ROB1.
TurnStation.sys
Contains helper functions for setting up and controlling the
washer unit. Could be loaded in all motion tasks but currently only
prepared for T_ROB1.
Washer.sys
Contains helper function for cyclic break check. Could be loaded
in all motion tasks but currently only prepared for T_ROB1.
SafeMove.sys
AirClean.sys
The module AirClean.sys handles functionality related to the air cleaning unit.
Description
Routine
Help procedure for calibrating air cleaning unit.
PROC CalibAirClean()
This procedure starts air through selected nozzle.
PROC
StartAirClean(num
nNozzle)
This procedure stops air through selected nozzle.
PROC Sto-
pAirClean(num nNozzle)
MarkingUnit.sys
The module MarkingUnit.sys handles functionality related to the marking unit.
Description
Routine
Help procedure for calibrating marking unit.
PROC CalibMarker()
Initiates marking unit, loads marking file and sets correct marking
string.
PROC SetMarker()
Start marking of a part.
PROC StartMarker()
Continues on next page
222
Product manual - FlexLoader SC 6000
3HAC051768-001 Revision: D
© Copyright 2014-2020 ABB. All rights reserved.
F FlexLoader RAPID reference
F.8 FlexLoader options functionality
Summary of Contents for FlexLoader SC 6000
Page 1: ...ROBOTICS Product manual FlexLoader SC 6000 ...
Page 8: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 78: ...This page is intentionally left blank ...
Page 172: ...This page is intentionally left blank ...
Page 174: ...This page is intentionally left blank ...
Page 176: ...This page is intentionally left blank ...
Page 178: ...This page is intentionally left blank ...
Page 182: ...This page is intentionally left blank ...
Page 184: ...This page is intentionally left blank ...
Page 186: ...This page is intentionally left blank ...
Page 192: ...This page is intentionally left blank ...
Page 224: ...This page is intentionally left blank ...
Page 283: ......