DHCP is used as standard setting.
Note
The network configuration on the factory network can be freely adopted to the
customers network.
Note
Please refer to the section on cyber security in the robot integrator's guide for
additional information.
Settings for Basler GigE cameras
Network setting for cameras
The following instructions assume that ABB’s standard IP address settings are
used. The same steps must be followed if alternative IP addresses are to be used.
The only difference is in the addresses that must be entered.
1 Connect the camera to the computer. Start
Pylon IP Configuration Tool
and
check that a connected camera can be seen. Select the camera.
xx1800000966
2 Select the radio buttons in the
IP Configuration Protocol
pane according to
the image below. Specify the correct
Device User ID
(
Camera1
,
Camera2
,
Camera3
,
Camera4
for the respective camera) and the correct data in the
Static IP address
pane (
Camera1 192.168.2.2
,
Camera2 192.168.2.3
,
Camera3 192.168.2.4
,
Camera4 192.168.2.5
,
Subnet Mask 255.255.255.0
,
GateWay 192.168.2.1
) as below.
Continues on next page
154
Product manual - FlexLoader Vision
3HAC051771-001 Revision: B
© Copyright 2014-2018 ABB. All rights reserved.
11 Commissioning
11.3.2 Settings
Continued
Summary of Contents for FlexLoader Vision
Page 1: ...ROBOTICS Product manual FlexLoader Vision ...
Page 8: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 62: ...This page is intentionally left blank ...
Page 96: ...This page is intentionally left blank ...
Page 180: ...This page is intentionally left blank ...
Page 218: ...This page is intentionally left blank ...
Page 286: ......
Page 287: ......