xx1800000986
Error management
Errors are read as single bits from up to four word memories in PLC. It is possible
to select whether the alarm for each word memory is to be camera specific or not.
If they are camera specific, the text
camera X
appears in the alarm text. Also note
that in a Siemens PLC, a byte swap occurs, which means that the start address
for the word in the PLC corresponds to
ErrorDescription 9
. Other bytes in the PLC
word memory start at
ErrorDescription 1
.
Description
Parameter
Enter memory location for error messages 1–16. Enter 0 if this ad-
dress is not to be used.
AddressErrorWord1
As above, but for error messages 17–32, 33–48, 49–64.
AddressError-
Word2,3,4
Text that is shown if corresponding bit in corresponding
AddressEr-
rorWord
is 1.
ErrorDescriptionX
xx1800000985
Continues on next page
Product manual - FlexLoader Vision
161
3HAC051771-001 Revision: B
© Copyright 2014-2018 ABB. All rights reserved.
11 Commissioning
11.3.4 Configuration of user-defined mechanical equipment
Continued