Operation with external operator panel
MasterSlave.xml
If a FlexLoader Vision Lite is controlled from the external operator panel, FlexLoader
Vision must be configured as
Slave (through TCP(IP)
.
Then the configuration file
MasterSlave.xml
must contain valid data for the IP
address of the external panel as well as the port it is to communicate on.
xx1800000528
MasterHandler.xml
If a FlexLoader Vision Lite is controlled from the external operator panel, the
following parameters must be changed in
MasterHandler.xml
on that external
operator panel.
•
Specify the language as per requirements.
•
Specify the IP address of the FlexLoader Vision computer as well as the port
number (same if specified in
MasterSlave.xml
).
•
The values for the
hasFlexLoaderVisionInterface
,
hasTeachIn
and
teachInType
parameters are specified according to the image below.
xx1800000970
FlexLoaderVisionLite.xml
The
FlexLoaderVisionLite.xml
file must be configured. If an external operator
panel is used, this file must be available for both FlexLoader Vision and
MasterHandler
.
Continues on next page
Product manual - FlexLoader Vision
247
3HAC051771-001 Revision: B
© Copyright 2014-2018 ABB. All rights reserved.
14 FlexLoader Vision Lite
14.5 FlexLoader Vision Lite configuration
Continued
Summary of Contents for FlexLoader Vision
Page 1: ...ROBOTICS Product manual FlexLoader Vision ...
Page 8: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 62: ...This page is intentionally left blank ...
Page 96: ...This page is intentionally left blank ...
Page 180: ...This page is intentionally left blank ...
Page 218: ...This page is intentionally left blank ...
Page 286: ......
Page 287: ......