PROFINET setup, see
. The Gate-PN cannot be used
to transfer safety-rated signals.
xx1800002563
DANGER
Installation and electrical connection of safety devices may only be performed
by authorized personnel.
Requirements for external equipment
The safety functions for external equipment are dependent on the design of that
equipment. General safety related information is transmitted and received in such
a way that the safety level PLd can also be fulfilled for the combined system, on
the condition that the external equipment fulfils PLd.
In order for the external equipment in the safety function ”emergency stop of all
equipment” to fulfil the PLd, the equipment must fulfil all PLd requirements.
In order for the external equipment in the safety function ”protective stop of all
equipment” to fulfil the PLd, the equipment must fulfil all PLd requirements.
Continues on next page
22
Application manual - FlexLoader Standard Safety Center
3HAC051769-001 Revision: E
© Copyright 2014-2020 ABB. All rights reserved.
3 Installation
Continued