2.8.6 Set Upper and Lower Limits Software Limits for track
Introduction
The Upper and Lower software limit of the track are software limits that prevent
the track from being jogged beyond the mechanical limit of the track.
WARNING
This is an important safety feature to prevent damage to the track. Ensure that
the track direction has first been set and the track has been calibrated before
performing this step.
Example
An example of the error message that is generated when the track is jogged beyond
its software limit is shown below:
xx1800001947
The Upper and Lower Limit of the track is the physical displacement distance from
the zero position to the limit position in meters. This depends on the length of the
track, and the location of the calibration pin (Also referred to as the Zero position
of the track).
The limits are in
MOC.CFG
, under the theme
ARM
.
The upper limit is called
upper_joint_bound
, and the lower limit is called
lower_joint_bound
. Both are expressed in meters.
In the example below the upper limit is set to 6 m and the lower limit is set to -0.005
m.
Continues on next page
104
Product manual - FlexTrack IRT501-66/66R/90/90R
3HAW050008590-001 Revision: C
© Copyright 20042018 ABB. All rights reserved.
2 Installation and commissioning
2.8.6 Set Upper and Lower Limits Software Limits for track
Summary of Contents for FlexTrack IRT501 Series
Page 1: ...ROBOTICS Product manual FlexTrack IRT501 66 66R 90 90R ...
Page 8: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 118: ...This page is intentionally left blank ...
Page 174: ...This page is intentionally left blank ...
Page 178: ...This page is intentionally left blank ...
Page 182: ...This page is intentionally left blank ...
Page 186: ...This page is intentionally left blank ...
Page 198: ...This page is intentionally left blank ...
Page 200: ...This page is intentionally left blank ...
Page 202: ......
Page 203: ......