Note/Illustration
Action
xx1800001978
Check the level of lubricant, if necessary replace
the cartridge and the battery (although the replace-
ment battery should be delivered with the replace-
ment cartridge, note that it is possible to use a
set of 3 pcs standard AA batteries).
2
For cartridge replacement, see the
memolub manual on the next page.
xx1800001979
Check that no pipe has been damaged, and that
the grease is distributed to each block and on the
pinion.
3
Memolub manual
The procedure below is based on the Memolub HPS user manual. It details how
to replace the grease cartridge.
Opening and closing the Memolub
Note
Action
xx1800001980
Opening the Memolub.
First place the Memolub on a flat and clean sur-
face. Push firmly with one hand on top of the
Memolub. With the other hand, hold the black
base and turn counterclockwise. Pull the transpar-
ent bell to open.
1
Continues on next page
132
Product manual - FlexTrack IRT501-66/66R/90/90R
3HAW050008590-001 Revision: C
© Copyright 20042018 ABB. All rights reserved.
3 Maintenance
3.5.3 Automatic lubrication system
Continued
Summary of Contents for FlexTrack IRT501 Series
Page 1: ...ROBOTICS Product manual FlexTrack IRT501 66 66R 90 90R ...
Page 8: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 118: ...This page is intentionally left blank ...
Page 174: ...This page is intentionally left blank ...
Page 178: ...This page is intentionally left blank ...
Page 182: ...This page is intentionally left blank ...
Page 186: ...This page is intentionally left blank ...
Page 198: ...This page is intentionally left blank ...
Page 200: ...This page is intentionally left blank ...
Page 202: ......
Page 203: ......