1.3.5 Risks associated with live electric parts
Voltage related risks, general
•
Although troubleshooting may, on occasion, have to be carried out while the
power supply is turned on, the robot must be turned off (by setting the mains
switch to OFF) when repairing faults, disconnecting electric leads and
disconnecting or connecting units.
•
The mains supply to the robot must be connected in such a way that it can
be turned off outside the robot's working space.
Voltage related risks, controller IRC5
A danger of high voltage is associated with the following parts:
•
Be aware of stored electrical energy (DC link, Ultra Cap unit) in the controller.
•
Units inside the controller, e.g. I/O modules, can be supplied with power from
an external source.
•
The mains supply/mains switch
•
The transformers
•
The power unit
•
The control power supply (230 VAC)
•
The rectifier unit (400-480 VAC and 700 VDC. Note: Capacitors!)
•
The drive unit (700 VDC)
•
The drive system power supply (230 VAC)
•
The service outlets (115/230 VAC)
•
The customer power supply (230 VAC)
•
The power supply unit for tools, or special power supply units for the
machining process.
•
The external voltage connected to the control cabinet remains live even when
the robot is disconnected from the mains.
•
Additional connections.
Voltage related risks, robot
A danger of high voltage is associated with the robot in:
•
The power supply for the motors (up to 800 VDC).
•
The user connections for tools or other parts of the installation (max. 230
VAC, see chapter Installation and commissioning in the Product manual).
Voltage related risks, tools, material handling devices, etc.
Tools, material handling devices, etc., may be live even if the robot system is in
the OFF position. Power supply cables which are in motion during the working
process may be damaged.
22
Product manual - FlexTrack IRT501-66/66R/90/90R
3HAW050008590-001 Revision: C
© Copyright 20042018 ABB. All rights reserved.
1 Safety
1.3.5 Risks associated with live electric parts
Summary of Contents for FlexTrack IRT501 Series
Page 1: ...ROBOTICS Product manual FlexTrack IRT501 66 66R 90 90R ...
Page 8: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 118: ...This page is intentionally left blank ...
Page 174: ...This page is intentionally left blank ...
Page 178: ...This page is intentionally left blank ...
Page 182: ...This page is intentionally left blank ...
Page 186: ...This page is intentionally left blank ...
Page 198: ...This page is intentionally left blank ...
Page 200: ...This page is intentionally left blank ...
Page 202: ......
Page 203: ......