3.5.6 Cables and connectors
Inspection of electrical operations
WARNING
Turn off all electric power, hydraulic and pneumatic pressure supplies to the
robot and for the FlexTrack IRT 501-66/66R/90/90R.
Check the cabling
Check monthly:
then ...
If any cables ...
replace the cable
have been damaged trough wear or pinching
Replace the cable, remove the cause of the
wear, or route the cable in a different way.
run against sharp edges
Check the connector
Check monthly:
•
All the connectors on the controller, the SMB box and the motor are firmly
tighten, and that there’s no damage to the cable outlet.
Inspection of the cable chain
Once a month check that the cable track shows no trace of excessive wear due to
rub on a fixed part. If one element is damaged, it is possible to replace it without
removing the whole chain from the FlexTrack.
xx1800001990
138
Product manual - FlexTrack IRT501-66/66R/90/90R
3HAW050008590-001 Revision: C
© Copyright 20042018 ABB. All rights reserved.
3 Maintenance
3.5.6 Cables and connectors
Summary of Contents for FlexTrack IRT501 Series
Page 1: ...ROBOTICS Product manual FlexTrack IRT501 66 66R 90 90R ...
Page 8: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 118: ...This page is intentionally left blank ...
Page 174: ...This page is intentionally left blank ...
Page 178: ...This page is intentionally left blank ...
Page 182: ...This page is intentionally left blank ...
Page 186: ...This page is intentionally left blank ...
Page 198: ...This page is intentionally left blank ...
Page 200: ...This page is intentionally left blank ...
Page 202: ......
Page 203: ......