2.7.4 Installation of the cable chain
WARNING
The FlexTrack cable chain is delivered assembled in the FlexTrack. If the cable
chain and/or its content must be modified upon installation, make sure that the
following recommendations are strictly followed. Improper installation of the
cable chain will result in premature wear or damages of the chain and the flexible
cables.
Checklist
Note/Illustration
Action
xx1800001918
A hole should be made in the cable tray to let all
the cables exit the FlexTrack. All cables should
exit the FlexTrack immediately at the end of the
chain.
If necessary, the edges of the cut tray area should
be covered with rubber edge guard.
1
xx1800001892
The cable tray should be absolutely free of any
object (cable, screw, etc.). The bottom of the cable
tray must be perfectly flat, without bump.
2
xx1800001920
In the cable chain, the cables should be separated
by the "separators", at least every 8 links.
That the mass of the cables and pipes inside the
chain should be balanced. Having all heavy cables
on the same side of the chain could cause prema-
ture wear.
3
Continues on next page
84
Product manual - FlexTrack IRT501-66/66R/90/90R
3HAW050008590-001 Revision: C
© Copyright 20042018 ABB. All rights reserved.
2 Installation and commissioning
2.7.4 Installation of the cable chain
Summary of Contents for FlexTrack IRT501 Series
Page 1: ...ROBOTICS Product manual FlexTrack IRT501 66 66R 90 90R ...
Page 8: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 118: ...This page is intentionally left blank ...
Page 174: ...This page is intentionally left blank ...
Page 178: ...This page is intentionally left blank ...
Page 182: ...This page is intentionally left blank ...
Page 186: ...This page is intentionally left blank ...
Page 198: ...This page is intentionally left blank ...
Page 200: ...This page is intentionally left blank ...
Page 202: ......
Page 203: ......