Parameterization
76
FV4000 / FS4000
D184B097U02
Buttons Menu item
Buttons Set parameter
Buttons
Configurable
parameters
Comments
„Enter“ „Enter“
„Data“
„Step“
Function
test
Iout
0
%
Manually controlled test of current output.
(100 % = 20 mA)
„Enter“
„Data“
„Step“
Q Simu-
lation
0.0
Hz
Selection: 0 ... 2500 Hz sensor frequency
Simulation (current and pulse output). Switch on by
entering the starting value in "Hz". Switch off by
entering "0" Hz. On changing to the process display,
the frequency can be modified with the "Data" and
"Step" buttons (± 5 Hz).
„Data“
„Step“
Main
FRAM
„Data“
„Step“
Backup
FRAM
„Enter“
„Data“
„Step“
Contact
output
Contact
off
The contact is switched on or off as required with the
"Data" and "Step" buttons.
„Enter“
„Data“
„Step“
Pulse
output
4Hz Rate
on
Selection:
0 = pulses
1 = no pulse