1 EASY-SETUP, for uncomplicated configuration
D184B122U02
S4
5
1
EASY-SETUP, for uncomplicated configuration
The EASY-SETUP function makes it possible to configure the converter for operation in the simplest and
quickest possible manner. For additional configuration information, see the detailed descriptions beginning
on Page 25.
Press any key to exit
from the process display
and scroll to
EASY-SETUP
Important!
The parameters can only
be changed after the Prog. Pro-
tection has been turned off.
EASY-SETUP
No = STEP
Jump to the menu level
see Page 25
Yes = ENTER
Language
English
EASY-SETUP completed
Return to Process Display
or use STEP to jump
to menu level Page 25
Units Qmax
l/s
Units Totalizer
Pulse Width
m3
0.1000 ms
Qmax
While in
„EASY-SETUP“ use the
C/CE Key to access
the next parameter.
Change parameter using the
„ENTER“-Function
Pulse Factor
50.000 l/s
1/m3
Damping 1 Tau
lout High Alarm
0.22 sec
23.000 mA
Display Mode
lout Low Alarm
4 small
3.6 mA
Display 1st Line
lout at Alarm
Q [units]
High Alarm
Display 2nd Line
Display 4th Line
Totalizer
→
F
Q [m/s]
Display 3rd Line
Totalizer
←
R