76J Pneumatic Fulscope Recorder
INTRODUCTION
4
Pressure Elements (letter codes, C, J, P, and Z are ALWAYS installed in the
upper left (second pen) position. For 2 or 3 pen instruments they can only be in
pen 2 position.)
A
Absolute Pressure Capsule
C
Differential Pressure meter body. Termination’s 183 through 186 required position for
2-pen instruments can only be selected once
Z
Differential Pressure meter body. Termination’s 191 through 197 required position for
2-pen instruments can only be selected once
D
Differential Pressure: Low Pressure unit
F
Gauge Pressure: low pressure units or Bourdon Springs
N
Gauge Pressure: Remote seal Filled system
Electrical input to motion converter
T
Electrical to motion element
Measuring element not included
L
Set-up for but no supply measuring element. Not valid for set-up for type 183 to 186,
and 191 to 197 Differential pressure meter body. Not valid unless pen code 2 is
selected
J
Set-up for but no supply type 183 to 186 Differential pressure meter body can only be
selected once Not valid unless pen code 2 is selected
P
Set-up for but no supply type 191 to 197 Differential pressure meter body can only be
selected once Not valid unless pen code 2 is selected
PEN 3 MEASURING ELEMENT TYPE - 7th Character
O
Third pen not installed
Temperature (filled system) Fill fluid:
G
Gas, SAMA class IIIB
M
Mercury, SAMA class VA and VB
V
Vapor, SAMA class II A, B, C, or, D
R
Monolex™, SAMA class IB
S
Ducalex™, SAMA class IA
Pressure Elements.(Differential pressure elements can not be installed in this
position)
A
Absolute Pressure Capsule
F
Gauge Pressure: low pressure units or Bourdon Springs
N
Gauge Pressure: Remote seal Filled system
Electrical input to motion converter
T
Electrical to motion element
Measuring element not included
L
Set-up for but no supply measuring element . Not valid unless pen code 3 is selected.
DOOR OPTIONS - 8th Character
1
Glass chart window
2
Glass chart window and door lock
3
Acrylic chart window
4
Acrylic chart window and door lock
Summary of Contents for Fulscope 76J Series Model C
Page 1: ...Fulscope 76J Series Model C Instructions Pneumatic Recorder ABB Instrumentation ...
Page 18: ...76J Pneumatic Fulscope Recorder OPERATION 14 Figure 7 Chart Plate and Chart Drive Components ...
Page 20: ...76J Pneumatic Fulscope Recorder OPERATION 16 ...
Page 34: ...76J Pneumatic Fulscope Recorder MAINTENANCE 30 ...
Page 39: ...76J Pneumatic Fulscope Recorder PARTS LIST 35 Figure 23 Two Pen Movement 93S115 ...
Page 40: ...76J Pneumatic Fulscope Recorder PARTS LIST 36 Figure 24 Three Pen Movement 93S99 ...
Page 52: ......