Note
Action
xx2200000347
Remove the four screws (pos. 2) to
loosen the Robifix connector (pos. 1).
Disconnect the male and female connect-
or. Cut the cable ties (pos. 3).
8
xx2200000348
Disconnect the current sensor and tem-
perature connector from the transformer.
9
xx2200000349
Remove the screws (pos. 1) and pressure
plates (pos. 2) connecting to the fixed and
movable leaf shunts.
10
xx2100000253
Remove the two screws (pos. 2) holding
the transformer (pos. 1).
11
Continues on next page
96
Product manual - GWT C9
3HAA010198-001 Revision: A
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.7 Replacement of the transformer
Continued