Oil temperature
Lubricating oil temperature at the inlet
WARNING
Machine damage and injury to personnel
If the oil temperature at the oil inlet exceeds the admissible range, this
may lead to machine damage and injury to personnel.
u
Observe oil temperature at the oil inlet according to the following
table.
Status for operation
Oil temperature at the
inlet
T
oil,inlet
[°C]
Admissible
30 … 95
Temporarily admissible (< 1 h) -> alarm
> 95
Not admissible -> stop engine
> 100
Not admissible -> do not start engine (before
start: preheat oil)
< 30
Lubricating oil temperature at the outlet
The oil temperature at the outlet is mainly dependant on:
¡
Lubricating oil temperature and pressure at the oil inlet
¡
Engine load and turbocharger speed
¡
Exhaust gas temperature.
The maximum admissible oil temperature at the outlet is listed in the fol-
lowing table. The specified oil outlet temperature is to be considered as
alarm value for the turbocharger operation and must be monitored ac-
cording to the current regulations.
Status for operation
Oil temperature at the
outlet
T
oil,outlet
[°C]
Admissible
≤
135
Temporarily admissible -> alarm
> 135
Not admissible -> stop engine
> 155
If the turbocharger has been operated for a longer period of time out-
side the admissible range, ABB Turbo Systems recommends having the
turbocharger inspected by an ABB Turbocharging Service Station.