Operation Manual / 4 Product description / A130-M.. - A145-M..
7
Eliminating malfunctions
Page 70 / 121
© Copyright 2017 ABB. All rights reserved.
HZTL4031_EN
Revision E
January 2017
7.4
Malfunctions when stopping
Runout noises
Possible causes
Remedy
Turbocharger Turbocharger contaminated
Clean (see chapter Periodic maintenance work
Bearing damaged
Check clearances (see chapter Axial clearance A and
91]). If clearances are outside
the tolerance or if in doubt, contact an ABB Turbo-
charging Service Station.
Rotor rubbing
Check clearances (see chapter Radial clearances N
99]). If clearances are outside the tolerance
or if in doubt, contact an ABB Turbocharging Service
Station.
Foreign object in the turbo-
charger
Dismantle turbocharger (see chapter Dismantling and
73]). In case of damage, replace the corre-
sponding parts or contact an ABB Turbocharging
Service Station.
Table 28: Malfunctions when stopping – Runout noises
Runout time too short
The runout time must be noted down as a reference. Because the runout time depends on the
oil viscosity, the runout time must always be measured at the same oil temperature.
If the runout time is significantly shorter in comparison to a previous measurement, the follow-
ing table must be observed.
Possible causes
Remedy
Turbocharger Turbocharger contaminated
Clean (see chapter Periodic
45])
Bearing damaged
Check clearances (see chapter Axial clearance A and
91]). If clearances are outside
the tolerance or if in doubt, contact an ABB Turbo-
charging Service Station.
Rotor rubbing
Check clearances (see chapter Radial clearances N
99]). If clearances are outside the tolerance
or if in doubt, contact an ABB Turbocharging Service
Station.
Foreign object in the turbo-
charger
Dismantle turbocharger (see chapter Dismantling and
73]). In case of damage, replace the corre-
sponding parts or contact an ABB Turbocharging
Service Station.
Table 29: Malfunctions when stopping – Runout time too short