Operation Manual / TPL65-A32 / -A33 / -A36 + TPL69-A32 / -A33
Taking out of operation at short notice
9
Possibilities for emergency repair
9.1
Page 99
Sept
em
be
r 2
014
H
ZT
L24
98_
EN
R
ev
is
ion A
Taking out of operation at short notice
Possibilities for emergency repair
9.1
WARNING
Danger of fire and explosion due to lubricating oil leaks
Leaking oil may ignite on hot surfaces. This can cause severe injuries
to personnel or accidents resulting in fatalities.
Cordon off danger area.
Raise the alarm, depending on situation shut down engine.
Seal leak.
Soak up oil and dispose of in an environmentally compatible manner.
Wear safety gloves against thermal risks.
CAUTION
Directives for taking out of operation
Serious damage to engine or property can be caused by non-
compliance with the directives for locking/blanking off the turbocharger
on the engine.
Follow the directives of the enginebuilder.
If the diesel engine must be capable of operation again as soon as
possible after damage to the turbocharger (emergency repair), the
following possibilities are available:
Locking turbocharger rotor
Fitting the cover plate
Shutting off inlets and outlets
Turbocharger bypass
9
9.1