Operation Manual / TPS48-D/E.. - TPS61-D/E..
Maintenance
5
Cleaning components mechanically
5.4
Page 71
© Copyright 2016 ABB. All rights reserved.
Sept
em
ber
2016
H
ZT
L2410_
EN
R
ev
is
ion
E
Turbine-end, non-rotating parts
WARNING
Handling operating materials and supplies
Swallowing or inhaling vapours of operating materials and supplies or
contact with them may be harmful to health.
Do not breathe in these substances and avoid contact with the skin.
Ensure proper ventilation.
Observe the information in the material safety data sheet for the op-
erating materials and supplies.
Wear personal protective equipment (PPE) according to the material
safety data sheet.
Comply with local legislation.
Wear safety goggles.
Wear safety gloves to protect against chemical hazards.
Wear a respiratory mask to protect against gases.
Baked layers of contamination, for example, from heavy fuel oil or coked
oil occur at the turbine end. The following parts, which are relevant in
terms of performance, can be cleaned in accordance with the description
below.
51000
Turbine casing
56001
Nozzle ring
52400
Gas outlet flange
Place contaminated parts in hot water or in a liquid such as carbon
remover to soften the contamination.
Brush away the contamination or remove with a steam cleaner.
Repeat the soaking and brushing if necessary.
Use clean water to completely clean parts of any solvents.
Dry components completely.
5.4.4