Operation Manual / TPL67-C.. - TPL71-C..
Taking out of operation at short notice
9
Fit cover plate
9.3
Page 122
© Copyright 2017 ABB. All rights reserved.
Febr
ua
ry
2017
HZ
TL2
488_
EN
Rev
is
ion D
Further measures and information for operation with a turbocharger with
cover plate on 4-stroke engines
4-stroke engine with one turbocharger
No further measures are necessary. The engine can be operated as a
naturally-aspirated engine according to the engine builder's instructions.
4-stroke engine with several turbochargers
No further measures are necessary on engines with separate air and ex-
haust gas receivers. The engine can be operated as a naturally-aspirated
engine according to the engine builder's instructions.
The air line must be closed off at the engine end because the undamaged
turbochargers build up a receiver pressure.
CAUTION
The engine can be operated according to the engine builder's instruc-
tions. Attention must always be paid to the speed of the undamaged
turbocharger. The speed limit n
Bmax
given on the rating plate must not
be exceeded.
Separate receivers