Operation Manual / TPL67-C.. - TPL71-C..
Mothballing turbocharger
10
Taking out of operation for more than 12
months
10.2
Page 126
© Copyright 2017 ABB. All rights reserved.
Febr
ua
ry
2017
HZ
TL2
488_
EN
Rev
is
ion D
Taking out of operation for more than
12 months
10.2
If the engine is taken out of service, the following can be done with the
turbocharger:
The turbocharger remains mounted on the engine.
The turbocharger casing remains mounted on the engine, but the rotor
and the bearing parts are removed and stored separately.
The turbocharger is removed completely, either as a whole or in indi-
vidual parts.
See the section Taking out of operation for up to 12 months, under Moth-
balling measures, for the measures always necessary when mothballing
turbocharger parts.
If the turbocharger remains mounted on the engine, refer to the section
Taking out of operation for up to 12 months, under Rotating the rotor in
stack draught.
If the entire turbocharger is removed or if the turbocharger is re-
assembled next to the engine using the individual parts:
Close all turbocharger openings using wooden covers and paraffin paper.
Suitable storage locations are only dry rooms where the relative humidity
is between 40 to 70 % and no condensation can form.
Condition of the mothballed turbocharger
Check the mothballed turbocharger parts for corrosion every year.
If there are signs of rust: Clean parts thoroughly and renew protection
against corrosion.