Operation Manual / TPL67-C.. - TPL71-C..
Maintenance
5
Cleaning components mechanically
5.5
Page 68
© Copyright 2017 ABB. All rights reserved.
Febr
ua
ry
2017
HZ
TL2
488_
EN
Rev
is
ion D
Turbine-end, non-rotating parts
WARNING
Handling operating materials and supplies
Swallowing or inhaling vapours of operating materials and supplies or
contact with them may be harmful to health.
Do not breathe in these substances and avoid contact with the skin.
Ensure proper ventilation.
Observe the information in the material safety data sheet for the op-
erating materials and supplies.
Wear personal protective equipment (PPE) according to the material
safety data sheet.
Comply with local legislation.
Wear safety goggles.
Wear safety gloves to protect against chemical hazards.
Wear a respiratory mask to protect against gases.
Baked-on layers of contamination, for example from heavy fuel oil or
coked oil, occur at the turbine end. The following performance-relevant
parts can be cleaned according to the following description.
56001 Nozzle ring
63000 Turbine diffuser
Place contaminated parts in hot water or in a liquid such as brake
cleaner, so that the contamination softens.
Brush off the contamination or remove it with a steam cleaner.
Repeat the soaking and brushing if necessary.
Completely remove any solvents from the parts in clean water.
Dry components completely.
5.5.2