Operation Manual / 4 Product description / A100-M axial
8
Disassembly and assembly
Page 69 / 113
© Copyright 2016 ABB. All rights reserved.
HZTL4033_EN
Revision A
July 2016
CAUTION
Clearance between blade tip and casing
Serious damage to machinery or property can result from the rubbing or
jamming of the blade tips on the casing.
Check that the blades do not rub on the turbine diffuser during disassem-
bly/assembly by rotating the rotor.
Figure 35: Removing cartridge group 2
1. Evenly press off cartridge group by screwing three press-off screws (90900) into the des-
ignated holes.
2. Using two guide rods (90490), move out cartridge group.
3. Fit supports (90450) and put down cartridge group.