Operation Manual / TPL65-A32 / -A33 / -A36 + TPL69-A32 / -A33
9 Taking out of operation at short notice / 9.1 Possibilities for emer-
gency repair
© Copyright 2019 . All rights reserved.
HZTL2498_EN
Rev.D
August 2019
9 Taking out of operation at short
notice
9.1 Possibilities for emergency repair
WARNING
Danger of fire and explosion due to lubricating oil leaks
Leaking oil may ignite on hot surfaces. This can result in serious injuries
to personnel or fatal accidents.
u
Cordon off danger area.
u
Raise the alarm and, depending on the situation, stop the engine.
u
Seal the oil leak.
u
Soak up oil and dispose of in an environmentally compatible manner.
Wear safety gloves to protect against thermal hazards.
CAUTION
Directives for taking out of operation
Serious damage to engine or property can be caused by non-compli-
ance with the directives for locking/blanking off the turbocharger on
the engine.
u
Follow the directives of the enginebuilder.
If the diesel engine must be capable of operation again as soon as pos-
sible after damage to the turbocharger (emergency repair), the following
possibilities are available:
¡
Locking turbocharger rotor
¡
Fitting the cover plate
¡
Shutting off inlets and outlets
¡
Turbocharger bypass
Page
98
/
118