Operation Manual / TPL65-A32 / -A33 / -A36 + TPL69-A32 / -A33
5 Maintenance / 5.3 Cleaning the compressor during operation
© Copyright 2019 . All rights reserved.
HZTL2498_EN
Rev.D
August 2019
5.3.2
Wet cleaning using external water-pressure vessel
(XC3)
Operating state prerequisites for wet cleaning XC3
NOTICE
To be able to carry out a satisfactory cleaning process which has been
tested and is recommended by ABB Turbo Systems, the following pre-
requisites must be fulfilled:
ü
Engine load 50 ... 85%
u
Start of cleaning cycle in accordance with following description for
wet cleaning operation with XC3.
Operating procedure for compressor wet cleaning with XC3
Operating the water pres-
sure vessel
u
The operating state prerequisites for compressor cleaning with XC3
must be fulfilled.
u
Remove sealing plug (X).
u
Fill vessel with required volume of clean water (see
table Cleaning
parameters
).
u
Screw in sealing plug (X).
Page
51
/
118