Operation Manual / TPL65-A32 / -A33 / -A36 + TPL69-A32 / -A33
8 Disassembly and assembly / 8.5 Removing cartridge group
© Copyright 2019 . All rights reserved.
HZTL2498_EN
Rev.D
August 2019
u
Turn the compressor casing (72000) together with the wall insert and
diffuser and set them down with surface (
F
) on an underlay.
WARNING
Tipping the compressor casing
Make sure the underlay does not shift.
u
Allow the compressor casing to rest only on surface (
F
).
u
Check the underlay and adjust it if necessary.
u
Remove the screws (72002).
u
Remove the diffuser (79000).
u
Remove the wall insert (77000) using swivel lifting eyes (90235).
u
Remove the O-ring (77005) from the wall insert.
Page
84
/
118