Operation Manual / 4 Product description / A130-M.. - A145-M..
5 Operation and service / 5.4 Stopping the engine
© Copyright 2017 ABB. All rights reserved.
HZTL4031_EN
Revision F
August 2017
5.4
Stopping the engine
CAUTION
Residual heat in the turbocharger
If the residual heat in the turbocharger is not adequately dissipated, it may
damage the engine.
u
Adequate cooling of the turbocharger must be ensured after stopping
the engine.
u
Run the engine for 5 ... 10 minutes at idling speed before stopping it.
u
Observe the oil pressure specified for engine idling
(see Table 6: Lubricating oil pressure,
.
¡
Post-lubricate water-cooled bearing casings until the rotors come to a standstill. Deac-
tivate post-lubrication as soon as the rotor comes to a standstill. Deviating procedures
must be coordinated with ABB Turbo Systems.
¡
For oil-cooled bearing casings, post-lubricate for 20 minutes if the turbine inlet temper-
ature (t
TE
) exceeds the following values when the engine is stopped:
– 550 °C with insulated casing
– 600 °C with non-insulated casing
At temperatures below the specified values, post-lubrication must be ensured until the
rotors come to a standstill. ABB Turbo Systems recommends post-lubrication for
10 minutes.
u
Observe the oil pressure specified for post-lubrication
(see Table 6: Lubricating oil pres-
.
Page
39
/
111