Operation Manual / 4 Product description / A100-M axial
8 Disassembly and assembly / 8.12 Removing and installing turbine-
end nozzle ring
© Copyright 2019 ABB. All rights reserved.
HZTL4033_DE
Revision C
February 2019
8.12
Removing and installing turbine-end nozzle ring
Removing nozzle ring
If only the nozzle ring needs to be removed, this can be dismantled at the turbine end.
CAUTION
Leaking connection
Reusing the removed spiral-wound gasket (61050) will result in leaking con-
nections. Spiral-wound gaskets may only be used once.
u
Provide
new
spiral-wound gasket (61050).
NOTICE
Blocked areas on nozzle ring
If a nozzle ring is blocked in some areas or is covered by loose parts, we
would recommend appointing an ABB Turbocharging Service Station to in-
spect the turbine blades and carry out a crack inspection.
In order to access the fixing screws, and loop round and transport the gas inlet casing, the
insulation has to be removed as required.
CAUTION
Damaged cleaning pipes
When looping around, ensure that any cleaning pipes present are not
pressed or damaged.
u
Never secure the lifting gear to the cleaning pipes.
Page
86
/