Operation Manual / 4 Product description / A150-M56/66/57/67 -
A155-M..
9 Dismantling and fitting with removed air inlet and gas outlet / 9.15
Installing the gas outlet flange
© Copyright 2020 ABB. All rights reserved.
HZTL4032_EN
Rev.P
March 2020
9.15
Installing the gas outlet flange
Fig. 67: Installing the gas outlet flange
1. If present: Insert the metal C-ring (57003) into the turbine casing (51000) and secure with
high-vacuum grease.
2. Fit swivel lifting eye (S) to the gas outlet flange (57002). Secure lifting gear to the swivel
lifting eye.
3. Install gas outlet flange in turbine casing (51000).
4. Measure radial clearance (R) (see chapter Radial clearances N and R).
Page
103
/
171