Operation Manual / 4 Product description / A100-M axial
2 Removal and installation / 2.3 Installing the turbocharger
© Copyright 2020 ABB. All rights reserved.
HZTL4033_EN
Rev.E
May 2020
Turbine-end (TE) foot
Fig. 12: Turbine-end foot
Product
Foot screw dimension
[mm]
Strength class
A170-M
M30
10.9
A175-M
M36
10.9
Table 3: Foot screws, dimension and strength class
Product
Dimension CE [mm]
a1
b1
c1
A170-M
82
ø32x23
68
A175-M
95
ø38x31
85
Table 4: Foot screws, dimension CE
Product
Dimension TE [mm]
a2 / a3
b2
c2 / c3
A170-M
94 / 124
ø32x11
56 / 45
A175-M
113 / 148
ø38x12
66 / 54
Table 5: Foot screws, dimension TE
Product
Number of cup springs X
A170-M
9
A175-M
11
Table 6: Foot screws, number of cup springs
Holes b1/b2 are needed to achieve the required clamping length. An additional drill hole is
not needed at the higher turbine-end foot side (01).
Page
14
/
113