Operation Manual / 4 Product description / A100-M axial
2 Removal and installation / 2.2 Removing the turbocharger
© Copyright 2020 ABB. All rights reserved.
HZTL4033_EN
Rev.E
May 2020
2.2
Removing the turbocharger
WARNING
Risk of tipping
If the turbocharger is not sufficiently supported or not supported at all dur-
ing removal and installation, it may tip over and cause severe injury to per-
sonnel or accidents resulting in fatalities.
u
Support the turbocharger at a suitable location.
u
Secure with lifting gear wherever possible.
u
If present: Loosen cable to speed sensor.
u
Disconnect all gas, air and lubricating oil pipes.
Fig. 6: Turbocharger suspension points
u
If present: Remove insulation segments on bearing casing and feet.
u
Attach lifting gear to the suspension lug of the bearing casing and through the boles on
the turbine-end foot.