Fitting wall insert
Fig. 63: Fitting wall insert
Product
Size
Tightening torque [Nm]
A170-M
M20
580
A175-M
M24
1000
Table 48: Tightening torque (72011)
1. Remove lifting device (90190 / 90195) and fixing segment (90192).
2. Slide wall insert (77000) into compressor casing up to stop and remove guide stud
(90319).
3. Secure wall insert with screws (72011) and washers (72008).
For assembly of the alternative air inlet, see section Installing air inlets.