Operation Manual / A150-M56/66/57/67 - A155-M..
15 Taking out of operation at short notice / 15.4 Fitting the cover
plate
© Copyright 2021 ABB. All rights reserved.
HZTL4032_EN
Rev.Q
January 2021
15.4
Fitting the cover plate
u
Remove turbocharger (see chapter
¡
Gas outlet casing removed
u
Fit the turbine casing with the gas outlet casing into the gas pipe again.
u
Attach the cover plate (see following section).
¡
Gas outlet casing not removed
u
Fit the turbine casing into the gas pipe and on the gas outlet casing again.
u
Attach the cover plate (see following section).
Fig. 128: Fitting the cover plate
u
Make sure that the oil connections in the bracket are equipped with gaskets.
1. Close opening in turbine casing (51000) with cover plate (01).
2. Thoroughly clean the fastening strips (51002) before assembly.
3. Coat the threads of the studs (51006) with high-temperature grease.
4. Fasten cover plate (01) to turbine casing (51000) with fastening strips (51002), Verbus
Ripp® washers (51003) and nuts (51007) and screw to bracket.