7.5
Changing the absorption element
The absorption element (81148) in uncoupled filter silencers must be replaced every 12000
hours of operation.
Disassembling the absorption element
Fig. 35: Disassembling the absorption element
1. Remove the filter silencer
(see Fig. 47: Removing the uncoupled filter silencer
.
2. Dismantle the hexagon-head screws (81152) with washers (81153) and mounting
plate (81149).
3. Remove the socket screws (81154), roll pins (81151), flanges (81145 / 81146) and absorp-
tion element (81148).