Operation Manual / A130-M.. - A145-M..
9 Dismantling and fitting / 9.7 Removing the compressor casing
© Copyright 2021 ABB. All rights reserved.
HZTL4031_EN
Rev.N
March 2021
Dismantling the wall insert
Fig. 46: Dismantling the wall insert
1. Knock the wall insert (77000) out of the compressor casing (72000) with a plastic tip
hammer.
2. Attach swivel lifting eye (S) to the compressor casing (72000) and the lifting gear.
3. Lift up the compressor casing (72000).
4. Remove and dispose of the O-ring (77005).