Operation Manual / Power2 850-M / 4.2 High-pressure stage
4 Disassembly and assembly / 4.7 Removing the cartridge group
© Copyright 2020 ABB. All rights reserved.
HZTL4063_EN
Rev.D
July 2020
CAUTION
Damage to cartridge group and toolbox cover
The turned-over toolbox cover may only be used for intermediate storage of
the cartridge group.
u
The cover must be on a level surface.
u
The cover may not be used to transport the cartridge group.
Fig. 12: Moving out cartridge group 3
9. Lower the cartridge group into the holders of the turned-over toolbox cover (90010) and
leave it secured to the crane.
Pay attention to note concerning aligning the cover.
10. Remove plate (90032), screw (90656), nut (90415) and plates (90031).
11. Remove the lamellar rings (64001).
Page
16
/
37